View Larger Image
|
|
6000IP Series Intergral Probe Models |
Range: 0 - 60 mils (1500 µm)
Resolution: 0.05 mil / 0.1 mil (1 µm/ 2 µm)
Substrates: F, N or FN
The 6000IP Series Integral Probe Coating Thickness Gauge is a versatile, rugged tester using magnetic and eddy current principles to measure coating thickness on both ferrous and non-ferrous metals, accurately and quickly. Integral Probe design offers maximum convenience and simplicity allowing for one-hand use, eliminating the external probe and cable which can be cumbersome in certain applications.
For typical paint and coating applications for a thickness range of 0-60 mils (0-1500 µm) applied to Ferrous substrates models include 6000-F1, 6000-F2 and 6000-F3. Models for Non-Ferrous applications include 6000-N1, 6000-N2 and 6000-N3. Models for use on both Ferrous and Non-Ferrous substrates include 6000-FN1, 6000-FN2 and 6000-FN3. For heavy-coating applications with a thickness range of 0-250 mils (0-6 mm) for use only on Ferrous substrates, models include 6000-FT1, 6000-FT2 and 6000-FT3.
All models are offered in three possible configurations; BASIC (1), STANDARD (2) and MEMORY (3) permitting users to select the feature set most suitable for their application. Refer to table below summarizing the different features included with each type "1", "2" or "3".
|

HiLo alarm audibly and visibly alerts when measurements exceed user-specified limits | Reversible Display enables right side up viewing whether the gage is in your hand or on a work table | Multi-lingual Menu; English, Spanish, French, German, Portuguese, Chinese, Japanese, Norwegian, Russian, Czech and Italian | Thick impact resistant Lexan® display is backlit for easy viewing in dim or dark environments | Built-in temperature compensation ensures measurement accuracy | No Calibration required for most applications | Average Zero Feature; allows for multiple "zero measurements" ideal for measurements on rough substrates |
| User-selected units of mils or µm | All models supplied with protective rubber holster with belt clip and NIST-Traceable Calibration Certificate supplied in Nylon carry case with shoulder strap | High Resolution mode increases the displayed resolution for use on applications that require greater precision | Made in the USA | Two (2) year warranty | Integral probe for one hand use on paint and coating applications in the range of 0-60 mils (0-1500 µm) |
|

 |

Feature Comparison Chart |
Basic
(1) |
Standard (2) |
Memory (3) |
| Hi-Lo limits audibly and visibly alerts when measurements exceed your specified limits |
- |
|
|
| Instantly calculate average, standard deviation, min/max thickness and number of readings while measuring |
- |
|
|
| Reading Storage Capacity |
- |
250 in one group |
10,000 in up to 1000 groups |
| SSPC PA2 feature set determines if film thickness over a large area conforms to user-specified min/max levels |
- |
- |
|
| PSPC 90/10 feature determines if a coating system complies with an IMO performance standard for protective coatings |
- |
- |
|
Built in clock to date and time stamp each stored measurement |
- |
- |
|
| Multiple stored calibration adjustments for measuring on a variety of substrate conditions |
- |
- |
|
| PosiSoft downloading and charting software (includes USB cable) |
- |
optional |
|
| Built-in IR port for printing to an optional portable printer |
- |
|
|
|

| | | | Complete kit comes with precision plastic shims, protective rubber holster with belt clip, 3 AAA batteries, instructions, wrist strap, nylon carrying case with shoulder strap, Certificate of Calibration traceable to NIST and two (2) year warranty |
 |

|
 |
Gage
Models
|
F1, F2, F3
N1, N2, N3
FN1, FN2, FN3
|
FT1, FT2, FT3
|
|
Range
|
0 - 60 mils |
0 -250 mils |
| 0 - 1500
um |
0 - 6 mm |
|
Accuracy
|
+
(0.05 mils + 1%)
0 - 2 mils
+ (0.1 mils + 1%)
> 2 mils |
+ (0.5 mils +
1%)
0 - 100 mils
+ (0.5 mil + 3%)
> 100 mils |
+
(1 um + 1%)
0 - 50 um
+ (2 um + 1%)
> 50 um |
+ (0.01 mm + 1%)
0 - 2.5 mm
+ (0.01 mm + 3%)
> 2.5 mm
|
| *Accuracies are stated as a fixed
value plus a percentage of the gage's actual reading. |
|

| Measuring principle: |
magnetic induction principle (Ferrous) eddy-current principle (Non-Ferrous) |
| Display |
Backlit & Reversible LCD |
| Data Output |
IR & USB - "2" & "3" Models Bluetooth - "3" Models |
| Surface Temp. |
Maximum 120 °F / 49 °C |
| Power |
3 AAA batteries, Included |
| Dimensions |
5.75" x 2.5" x 1.2" (146 x 64 x 31 mm) |
| Weight |
5.8 oz. (165 g) without batteries |
| Protection Class |
Meets or exceeds IP5X, Solvent, acid, oil, water & dust resistant |
| Warranty |
2 Years |
| Calibration Certificate |
Certificate of Calibration showing traceability to NIST included |

|
6000GP Series General Purpose Models |  |
External probe for general purpose paint and coating applications
| | Click image for more info | | ___________________________________________ |
|
6000MP Series Micro Probe Models |  |
Micro Probe for measuring thin coatings, small parts or hard to reach areas or spots
| | Click image for more info | | ___________________________________________ |
|
6000TC Series Thick Coating Model |  |
For thick paint and coatings from 60 to 250 mils
| | Click image for more info | | ___________________________________________ |
|
6000TCX Series Extra Thick Coating Models |  |
For extra thick paint and coatings from 150-500 mils
| | Click image for more info | | ___________________________________________ |
|
IR-PRINTER
|  |
Wireless, battery-operated
Prints both text and graphics
Receives data via an invisible infrared beam
| | Click image for more info
|

|


|