View Larger Image
|
|
DX2 Tension Meter | A precise jeweled movement, choice of ball bearing mounted rollers and rugged cast aluminum housing makes the DX2 ideal for the toughest production floor application.
Built-in mounting holes permit fixed installation for continuous in-line use.
Built-in material thickness compensator maximizes accuracy when using filaments of different diameters. (Standard on model DX2-SP and higher ranges)
|

Thumb-operated, roller shifting mechanism and exclusive snare-guide automatically guides the moving filament into the V-grooves eliminating breaks and snags.
| Front filament loading permits the operator to observe running material, rollers and dial face at all times.
| DX2's are individually calibrated for highest accuracy. |
| NIST calibration available | DX2's hard-coated aluminum, V-grooved rollers are rated for speeds up to 2000 m/min or, optionally, up to 5000 m/min. | Finger Support: We recommend mounting a finger support for higher tension ranges (included)
 |
|

 |

| Model |
Range | Outer Roller Spacing c:c | Calibration Material | Thickness Compensator |
| DX2-3 |
3-30 g | 38 mm | PA: 0.12 mm Ø | NA |
| DX2-5 |
5-50 g | 38 mm | PA: 0.12 mm Ø | NA |
| DX2-12 |
20-120 g | 38 mm | PA: 0.12 mm Ø | NA |
| DX2-20 |
20-200 g | 38 mm | PA: 0.12 mm Ø | NA |
| DX2-40 |
20-400 g | 38 mm | PA: 0.20 mm Ø | NA |
| DX2-SP |
20-1000 g | 38 mm | PA: 0.30 mm Ø | Standard |
| DX2-EX |
100-1000 g | 38 mm | PA: 0.30 mm Ø | Standard |
| DX2-200 |
200-2000 g | 100 mm | PA: 0.50 mm Ø | Standard |
| DX2-500 |
400-5000 g | 100 mm | PA: 0.80 mm Ø | Standard |
| DX2-1K |
2-10 Kg | 100 mm | PA: 1.00 mm Ø | Standard |
| DX2L-2K |
5-20 Kg | 150 mm | PA: 1.50 mm Ø | Standard |
| DX2L-3K |
5-30 Kg | 250 mm | | Standard |
| DX2L-5K |
5-50 Kg | 250 mm | | Standard | | |
Calibration to customized material:
If process material differs significantly from the standard calibration material in diameter, rigidity or shape, special calibration using customer supplied samples is recommended. For this purpose a material sample of about 15 ft. should be supplied.
Click Here For Sample Dial Faces
 |
|   |

|
DX2S Stationary Tension Meter |  |
Fixed mount design for continuous measurement
Option adjustable "max" & "min" tension detector contacts can provide a low voltage signal when tension exceed user-set limits
| | Click image for more info | | ___________________________________________ |
|
Roller Guide Available Rollers for Hand-Held Tension Meters |  |
| | Click image for more info
|

Air Damping (A)

An adjustable, precision air dashpot provides steady
tension reading as tension fluctuate. |
 |
| |
Lever (L)

A heavy duty, lever-operated mechanism moves the outer rollers
for easy acquisition of the running filament. Recommended for models of
10 Kg or higher. |
 |
| |
Memory Pointer (M)

Designed to retain the peak value as tensions fluctuate.
Manually reset by using the knob located in the center of the dial. |
 |
| |
|
|

| | | | The DX2 Tension Meter is supplied as a complete kit including meter and instruction manual in a foam-fitted hard-plastic carrying case. |
 |

| Accuracy |
± 1% of full scale or ± 1 graduation mark on scale |
| Diameter of Scale |
41 mm |
| Maximum Speed |
2000 m/min (standard) 3500 m/min (K) 5000 m/min (HS) |
| Outer roller distance, c:c |
DX2-5 to DX2-EX: 38 mm DX2-200 to DX2-1k: 100 mm DX2-2K: 150 mm DX2-3K to DX2-5K: 250 mm |
| Roller Material |
Hard-coated aluminum (standard) Hardened steel (ST) Chromed Steel (w) Ceramic (CE) Plastic (PL) |
| Housing Material |
Die-cast aluminum |
| Dimensions |
225 x 90 x 44 mm (8.6" x 3.5" x 1.7") |

|


|