6000-PROBES Probes For Use With 6000 Series | Spare / Replacement probes for 6000 Series Coating Thickness Gauges. All probes are supplied with a NIST Traceable calibration certificate. |
|
|
Probe Models: |
FS, NS, FNS |
Range: |
0 -60 mils |
| 0 - 1500 um |
Accuracy*: |
+ (0.05 mils + 1%) 0 - 2 mils
+ (0.1 mil + 1%) > 2 mils |
+ (1 um + 1%) 0 - 50 um
+ (2 um + 1%) > 50 um |
| *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
|
|
Probe Models: |
FRS, NRS, FNRS |
Range: |
0 -60 mils |
| 0 - 1500 um |
Accuracy*: |
+ (0.05 mils + 1%) 0 - 2 mils
+ (0.1 mil + 1%) > 2 mils |
+ (1 um + 1%) 0 - 50 um
+ (2 um + 1%) > 50 um |
| *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
|
|
 |
Probe
Models
|
F1, F2, F3
N1, N2, N3
FN1, FN2, FN3
|
FT1, FT2, FT3
|
|
Range
|
0 - 60 mils |
0 -250 mils |
| 0 - 1500
um |
0 - 6 mm |
|
Accuracy
|
+
(0.05 mils + 1%)
0 - 2 mils
+ (0.1 mils + 1%)
> 2 mils |
+ (0.5 mils +
1%)
0 - 100 mils
+ (0.5 mil + 3%)
> 100 mils |
+
(1 um + 1%)
0 - 50 um
+ (2 um + 1%)
> 50 um |
+ (0.01 mm + 1%)
0 - 2.5 mm
+ (0.01 mm + 3%)
> 2.5 mm
|
| *Accuracies are stated as a fixed
value plus a percentage of the gage's actual reading. |
|
  |
Probe Models: |
F0S |
N0S
|
Range: |
0 - 45 mils |
0 - 25 mils |
| 0 - 1143 µm |
0 - 625 µm |
Accuracy*: |
+ (0.02 mils + 1%) 0 - 4 mils
+ (0.1 mils + 3%) > 4 mils |
+ (.5 µm + 1%) 0 - 100 µm
+ (2 µm + 3%) > 100 µm |
| *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
|
|
Probe Models: |
F45S |
N45S
|
Range: |
0 - 45 mils |
0 - 25 mils |
| 0 - 1143 µm |
0 - 625 µm |
Accuracy*: |
+ (0.02 mils + 1%) 0 - 4 mils
+ (0.1 mils + 3%) > 4 mils |
+ (.5 µm + 1%) 0 - 100 µm
+ (2 µm + 3%) > 100 µm |
| *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
|
|
Probe Models: |
F90S |
N90S
|
Range: |
0 - 45 mils |
0 - 25 mils |
| 0 - 1143 µm |
0 - 625 µm |
Accuracy*: |
+ (0.02 mils + 1%) 0 - 4 mils
+ (0.1 mils + 3%) > 4 mils |
+ (.5 µm + 1%) 0 - 100 µm
+ (2 µm + 3%) > 100 µm |
| *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
|
|
Probe Models: |
FNTS
|
Range: |
0 -250 mils |
| 0 - 6 mm |
Accuracy*: |
+ (0.5 mils + 1%) 0 - 100 mils
+ (0.5 mil + 3%) > 100 mils |
+ (0.01 mm + 1%) 0 - 2.5 mm
+ (0.01 mm + 3%) > 2.5 mm |
| *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
|
|
Probe Models: |
FTS |
Range: |
0 -250 mils |
| 0 - 6 mm |
Accuracy*: |
+ (0.5 mils + 1%) 0 - 100 mils
+ (0.5 mil + 3%) > 100 mils |
+ (0.01 mm + 1%) 0 - 2.5 mm
+ (0.01 mm + 3%) > 2.5 mm |
| *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
|
|
Probe Models: |
FKS |
NKS |
Range: |
0 - 500 mils |
| 0 - 13 mm |
Accuracy*: |
+ (1 mils + 3%) 0 - 500 mils + (0.02 mm + 3%) 0 - 13 mm |